LINE CLEARANCE CHECKLIST FOR DISPENSING AREA

LINE CLEARANCE CHECKLIST FOR DISPENSING AREA

Check the Cleanliness of Dispensing area and RLAF & its filter.

RLAF unit is operating for at least 15 minutes prior to dispensing.

Are all the remnants of the previous product removed?

Check the status board of dispensing area for the following details: Product Name, Batch No, Mfg. Date, Exp. Date Batch Size and Match with BMR.

Dispensing booth equipment is clean and dust free.

Relevant weighing balances are calibrated.

Containers & equipment used for weighing and transferring the material are cleaned and dried.

Check whether the R.M. Requisition Sheet is ready and signed by an authorized person.

Ensure the Room Relative Humidity: NMT 50 % Room Temperature:

  NMT 27 0C should be within the limit & pressure differential should be within the limit.

Dispensed the material as per FEFO System.

DATE (Date required in case of LC to be done in shift change or day of working change).