CEFEPIME AND AMIKACIN FOR INJECTION

CEFEPIME AND AMIKACIN  FOR INJECTION 1.25GM PRODUCT PROFILE Generic Name: CEFEPIME & AMIKACIN FOR INJECTION Strength :.25 GM Lot size: 70500 units Average Filled Weight: 2.15 gm/vial Label Claim:   Each vial contains: Cefepime Hydrochloride USP equivalent to Cefepime  ___________ 1000 mg Amikacin Sulphate IP equivalent to Amikacin _____________250 mg Shelf Life:  2 Years Dosage Form: … Read more

CARBOPLATIN INJECTION 150MG/15ML

CARBOPLATIN INJECTION 150MG/15ML CARBOPLATIN  is a chemotherapy drug. It targets fast-dividing cells, like cancer cells, and causes these cells to die. This medicine is used to treat ovarian cancer and many other cancers. Carboplatin  Injection is an anticancer medicine that is used in the treatment of ovarian cancer (cancer of the ovary, part of the female … Read more

AMOXYCILLIN CLAVULANATE FOR INJECTION

AMOXYCILLIN CLAVULANATE  FOR INJECTION PRODUCT INTRODUCTION AMOXYCILLIN- CLAVULANATE FOR INJECTION  is a penicillin-type of antibiotic that helps your body fight infections caused by bacteria. It is used to treat infections of the lungs (e.g., pneumonia), ear, nasal sinus, urinary tract, skin, and soft tissue. It will not work for viral infections such as the common … Read more

INSTALLATION QUALIFICATIONS OF DISPENSING BOOTH

INSTALLATION QUALIFICATIONS OF DISPENSING BOOTH TABLE OF CONTENT Purpose Scope Responsibilities Procedure Installation Qualification tests Documents & Drawings Verification Verification of Technical Specification for In-House & sub-components / Bought out items Utilities Verification Material of Construction Verification Critical Instrument Calibration Verification Installation Qualification Tests Status Data Analysis, Summary of IQ & Recommendations Amendment Record Conclusion … Read more

SOP for Operating Procedure for Gelatin Storage Vessel

SOP for Operating Procedure for Gelatin Storage Vessel Check the ‘CLEANED’ status label duly filled and signed on the Gelatin Storage Vessel, then unwrap the cling film. Ensure the cleanliness of the Gelatin Storage Vessel. Affix ‘BATCH IN-PROCESS’ status label on Gelatin Storage Vessel duly filled and signed. Record all observations in line clearance record. … Read more

OPERATION OF REVERSE OSMOSIS SYSTEM

OPERATION OF REVERSE OSMOSIS SYSTEM To provide the operating procedure for the Reverse Osmosis system. This procedure covers the operating procedure for the Reverse Osmosis system. PROCEDURE The Reverse Osmosis system is fed with softened water stored in a tank with a capacity of 5000 Liter. The feed pump pumps water from the tank to … Read more

Cleaning procedure for Softened Water Storage Tanks

Cleaning procedure for Softened Water Storage Tanks To implement the cleaning procedure for Softened Water Storage Tanks. This SOP covers the cleaning procedure for Softened Water Storage Tanks. Procedure: Ensure that there is no production activity in the concerned area. Turn off the tank which should be cleaned and put a sign “UNDER PREVENTIVE MAINTENANCE” … Read more

Procedure of the replacement procedure for the Purified Water Pump

To implement and procedure of the replacement procedure for the Purified Water Pump. This SOP covers the replacement procedure for the Purified Water Pump. PROCEDURE Ensure that there is no production activity in the concerned area. Turn on the Reverse Osmosis system and put a sign “UNDER PREVENTIVE MAINTENANCE”. Drain water from the purified water … Read more

Procedure of storing uniforms for microbiological analysis

The procedure of storing uniforms for microbiological analysis To lay down the Procedure of storing uniforms for microbiological analysis This SOP is applicable to provide the long and qualitative operation of  UV -cabinets,s and the sterility of used materials. PROCEDURE: General cleaning After another replacement germicidal lamp: Power off the UV cabinet. Thoroughly clean the … Read more

Operation and calibration procedures of viscometer

Operation  and calibration  procedures of viscometer Operation and calibration procedures of viscometer. PROCEDURE  Plugin the instrument Start the instrument by pressing the ON/OFF button on the back panel The following is displayed: REMOVE SPINDLE PRESS ANY KEY REMOVE SPINDLE PRESS ANY KEY Remove the spindle and press any key. The following is displayed: REPLACE SPINDLE … Read more